Abstract Due to some of the unreasonable simplification and conclusion in some textbooks and literatures for the calculation of abrupt change range when weak acid is titrated, a more accurate formula was deduced by taking account of the actual composition of the solution near the stoichiometric point,and the criteria for the accurate titration of weak acid was obtained.
LIU Yu-Ying, WANG Ping, LIU Qing, LIN Hong-Tao, XIAO Hai-Bin. Calculation of Abrupt Change Range for Titration of Weak Acid by Strong Base[J]. , 2019, 40(22): 88-90.